PITCHED ROOF
DuPont™ Tyvek® Supro / Supro Plus
The market leading breather membrane: • Durable (see independent test
• Available with integrated results at www.tyvek.co.uk)
tape: Supro Plus • For all supported and unsupported
• BBA certificate: 08/4548 pitched roof applications -
• Windtight, unrestricted use warm, hybrid and cold roofs
for BS 5534:2014 • For Scottish sarking board systems
• 4s month UV stable • For low pitched metal roofs,
• No ventilation required
wall and floor applications
• Extremely water-resistant Code Description
• Air tight 2495980 1 x 50m
• Vapour-permeable 2495981 1.5 x 50m
• Providing superior air and moisture
management for commercial
and residential buildings
DuPont™ AirGuard® Smart • Very robust - offering versatility in
site work - Airtight- Transparent
• An innovative membrane with allowing the timber members to
variable sd-value which adapts be easily located for fixing -
for superior drying out potential
and humidity protection. • CE-conformity for vapour
control layer (EN 13984) Type
• Extreme Sd Value range from 0.05 m B - Reaction to Fire: Class E
to more than 30 m, therefore highly
adaptable: one of the widest vapour Code Description
resistance spans known in the market.
2496108 1.5 x 50m
• Combines drying-out and vapour
control function in one layer. High
drying-out potential = high protection
against structural damage High
tensile strength offering superior
insulation support/retention
DuPont™ AirGuard® Control
• A mechanically robust AVCL for • CE-conformity for vapour
airtightness and limited humidity control layer (EN 13984) Type
protection in roofs, walls and ceilings. A Reaction to Fire: Class E
• BBA certificate: 08/4548 & 90/2548 • Reduces convective heat losses
• Limited vapour transmission • Reduces risk of condensation
• Airtight and water resistant
• Superior mechanical strength into the insulation
• Good mechanical strength • Water vapour transmission (Sd) 5m
Code Description
2496000 1.5 x 50m
DuPont™ AirGuard® Reflective
• An AVCL for normal to extreme interior • Reduces heat losses by increasing
humidity climates that enhances of R-value of the construction
thermal insulation performance.
• Considerably reduces risk of
• BBA certificate: 08/4548 & 90/2548 condensation into the insulation
• Extreme vapour resistance
• Airtight and water resistant • Reduces convective heat losses
• Reflects ca. 95% of radiant heat • CE-conformity for vapour
• Superior mechanical strength (grid)
• Reaction to Fire: Class E control layer (EN 13984)
Code Description
2495999 1.5 x 50m
DuPont™, Tyvek® and AirGuard® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates. Photo credit: DuPont.